Calculator: Resistor self-heating

Enter the labelled inputs to calculate: Power (W); Temperature (°C).

Power (W)
1
Temperature (°C)
45

How the calculation works

P=I²R; T=Ta+Pθ

Uses steady-state power and a series thermal-resistance path. Temperature coefficients, transient heating and parallel cooling paths are excluded. Buck/boost ripple assumes ideal continuous conduction; negative valley current is rejected. Use RMS current for resistive loss and sinusoidal capacitor calculations.

Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

Frequently asked questions

How is the result calculated?

P=I²R; T=Ta+Pθ

What assumptions apply?

Uses steady-state power and a series thermal-resistance path. Temperature coefficients, transient heating and parallel cooling paths are excluded. Buck/boost ripple assumes ideal continuous conduction; negative valley current is rejected. Use RMS current for resistive loss and sinusoidal capacitor calculations.

How precise are the displayed results?

Numerical results show up to ten significant digits. Rounding does not improve the accuracy of the input measurements or the model. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

How we verified this calculator

The calculator is checked against 3 reference cases computed independently of its code. Last passed: .

# Inputs Expected result
1
Resistance (Ω) = 100
Current (A) = 0.1
Thermal resistance (K/W) = 50
Temperature (°C) = 25
Power (W): 1
Temperature (°C): 75
2
Resistance (Ω) = 0.1
Current (A) = 3
Thermal resistance (K/W) = 80
Temperature (°C) = 40
Power (W): 0.9
Temperature (°C): 112
3
Resistance (Ω) = 10
Current (A) = -0.2
Thermal resistance (K/W) = 120
Temperature (°C) = 0
Power (W): 0.4
Temperature (°C): 48