Calculator: Linear resistor temperature derating

Enter the labelled inputs to calculate: Power Pmax (W); Coefficient (%).

Power Pmax (W)
0.5
Coefficient (%)
50

How the calculation works

k=clamp[(Tmax−Ta)/(Tmax−T₀),0,1]; Pmax=kPrated

Ideal op-amp models exclude supply-rail clipping, offsets and bandwidth. Schmitt thresholds assume an inverting input, ground divider and symmetric saturation. LM317 current is nominal and requires adequate headroom/current/thermal capability from its data sheet. Derating uses the entered linear endpoints. Ripple assumes ideal continuous conduction; boost excludes ESR and buck sums capacitor/ESR estimates.

Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

Frequently asked questions

How is the result calculated?

k=clamp[(Tmax−Ta)/(Tmax−T₀),0,1]; Pmax=kPrated

What assumptions apply?

Ideal op-amp models exclude supply-rail clipping, offsets and bandwidth. Schmitt thresholds assume an inverting input, ground divider and symmetric saturation. LM317 current is nominal and requires adequate headroom/current/thermal capability from its data sheet. Derating uses the entered linear endpoints. Ripple assumes ideal continuous conduction; boost excludes ESR and buck sums capacitor/ESR estimates.

How precise are the displayed results?

Numerical results show up to ten significant digits. Rounding does not improve the accuracy of the input measurements or the model. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

How we verified this calculator

The calculator is checked against 3 reference cases computed independently of its code. Last passed: .

# Inputs Expected result
1
Power (W) = 0.25
Temperature T₀ (°C) = 70
Temperature Tmax (°C) = 155
Temperature Ta (°C) = 100
Power Pmax (W): 0.1617647059
Coefficient (%): 64.70588235
2
Power (W) = 1
Temperature T₀ (°C) = 70
Temperature Tmax (°C) = 155
Temperature Ta (°C) = 40
Power Pmax (W): 1
Coefficient (%): 100
3
Power (W) = 2
Temperature T₀ (°C) = 25
Temperature Tmax (°C) = 175
Temperature Ta (°C) = 160
Power Pmax (W): 0.2
Coefficient (%): 10

How we test our calculators →

Also try:

Back to category →