Calculator: Net thermal radiation
Enter the labelled inputs to calculate: Power (W).
Enter a finite value within the formula’s domain and supported numeric range.
How the calculation works
Q̇=εσA(T₁⁴−T₂⁴); σ=5.670374419×10⁻⁸ W/(m²·K⁴)
Gray surface exchanging radiation with a large uniform enclosure; temperatures are in kelvins. View-factor and reflection corrections are excluded.
Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.
Frequently asked questions
How is the result calculated?
Q̇=εσA(T₁⁴−T₂⁴); σ=5.670374419×10⁻⁸ W/(m²·K⁴)
What assumptions apply?
Gray surface exchanging radiation with a large uniform enclosure; temperatures are in kelvins. View-factor and reflection corrections are excluded.
How precise are the displayed results?
Numerical results show up to ten significant digits. Rounding does not improve the accuracy of the input measurements or the model. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.
How we verified this calculator
The calculator is checked against 3 reference cases computed independently from the sources below. Last passed: .
| # | Inputs | Expected result |
|---|---|---|
| 1 |
Emissivity = 1
Area (m²) = 1
Temperature T₁ (K) = 400
Temperature T₂ (K) = 300
|
Power (W): 992.3155233
|
| 2 |
Emissivity = 0.9
Area (m²) = 2.5
Temperature T₁ (K) = 350
Temperature T₂ (K) = 290
|
Power (W): 1012.175443
|
| 3 |
Emissivity = 0.1
Area (m²) = 0.5
Temperature T₁ (K) = 1000
Temperature T₂ (K) = 1200
|
Power (W): -3043.856988
|
Sources
- CODATA Recommended Values of the Fundamental Physical Constants: 2022 — Stefan–Boltzmann constant σ — National Institute of Standards and Technology