Calculator: Layered wall U-value

Enter the labelled inputs to calculate: Thermal resistance (m²·K/W); U-value (W/(m²·K)).

Thermal resistance (m²·K/W)
2.92
U-value (W/(m²·K))
0.3424657534

How the calculation works

R=Rsi+d₁/λ₁+d₂/λ₂+Rse; U=1/R; d(m)=d(mm)/1000

Use net dimensions and the geometric model shown. Material density, porosity, efficiency and allowances are user supplied where required. Whole units are rounded up only where stated.

Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

Frequently asked questions

How is the result calculated?

R=Rsi+d₁/λ₁+d₂/λ₂+Rse; U=1/R; d(m)=d(mm)/1000

What assumptions apply?

Use net dimensions and the geometric model shown. Material density, porosity, efficiency and allowances are user supplied where required. Whole units are rounded up only where stated.

How precise are the displayed results?

Numerical results show up to ten significant digits. Rounding does not improve the accuracy of the input measurements or the model. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.

How we verified this calculator

The calculator is checked against 3 reference cases computed independently of its code. Last passed: .

# Inputs Expected result
1
Thickness d₁ (mm) = 100
Thermal conductivity λ₁ (W/(m·K)) = 0.04
Thickness d₂ (mm) = 200
Thermal conductivity λ₂ (W/(m·K)) = 0.8
Thermal resistance Rsi (m²·K/W) = 0.13
Thermal resistance Rse (m²·K/W) = 0.04
Thermal resistance (m²·K/W): 2.92
U-value (W/(m²·K)): 0.3424657534
2
Thickness d₁ (mm) = 150
Thermal conductivity λ₁ (W/(m·K)) = 0.035
Thickness d₂ (mm) = 250
Thermal conductivity λ₂ (W/(m·K)) = 0.45
Thermal resistance Rsi (m²·K/W) = 0.13
Thermal resistance Rse (m²·K/W) = 0.04
Thermal resistance (m²·K/W): 5.011269841
U-value (W/(m²·K)): 0.1995502201
3
Thickness d₁ (mm) = 50
Thermal conductivity λ₁ (W/(m·K)) = 0.022
Thickness d₂ (mm) = 100
Thermal conductivity λ₂ (W/(m·K)) = 1.7
Thermal resistance Rsi (m²·K/W) = 0.1
Thermal resistance Rse (m²·K/W) = 0.04
Thermal resistance (m²·K/W): 2.471550802
U-value (W/(m²·K)): 0.4046042667