Gas Heating from Entered Area and Heat Demand
Calculate using the labelled inputs: Gas Heating from Entered Area and Heat Demand.
Enter a finite value within the formula’s domain and supported numeric range.
Calculation and assumptions
useful=area·annual_specific_demand; input=useful/(efficiency/100); volume=input/entered_kWh_per_m3; total=round(volume·price_per_m3,2)+annual_fixed.
An entered-demand scenario, not a building assessment, measured bill or equipment sizing calculation. No insulation class or official heat-demand norm is selected automatically. Efficiency is an entered conversion factor; its calorific basis must agree with the entered gas energy per m³. No certified boiler performance is implied. Demand already represents annual useful heat; do not apply hours or days again. Inputs allow six decimals, annual fixed charge two. Variable charge rounds once to cents, halves away from zero. Monthly result is an annual average, not seasonal use. Zero demand keeps fixed charge and makes charge/useful-kWh undefined. No current tariffs, taxes or subsidy eligibility supplied. In one chosen two-decimal currency; no taxes or current market rates are supplied.
Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.
Frequently asked questions
How is the result calculated?
useful=area·annual_specific_demand; input=useful/(efficiency/100); volume=input/entered_kWh_per_m3; total=round(volume·price_per_m3,2)+annual_fixed.
What assumptions apply?
An entered-demand scenario, not a building assessment, measured bill or equipment sizing calculation. No insulation class or official heat-demand norm is selected automatically. Efficiency is an entered conversion factor; its calorific basis must agree with the entered gas energy per m³. No certified boiler performance is implied. Demand already represents annual useful heat; do not apply hours or days again. Inputs allow six decimals, annual fixed charge two. Variable charge rounds once to cents, halves away from zero. Monthly result is an annual average, not seasonal use. Zero demand keeps fixed charge and makes charge/useful-kWh undefined. No current tariffs, taxes or subsidy eligibility supplied. In one chosen two-decimal currency; no taxes or current market rates are supplied.
How precise are the results?
Monetary totals use two decimal places with the stated rounding rule; other numbers show up to ten significant digits. Display precision does not improve input accuracy. Values must satisfy the formula’s domain. Nonzero results too small or too large for reliable representation are rejected.
What heat demand should I enter?
Use the annual useful heating demand from your energy certificate or audit in kWh/m² per year; well-insulated new and uninsulated old houses differ several-fold, so no fixed categories are built in. Efficiency may exceed 100 % for condensing boilers rated on net calorific value.
How we verified this calculator
The calculator is checked against 2 reference cases computed independently of its code. Last passed: .
| # | Inputs | Expected result |
|---|---|---|
| 1 |
Heated floor area (m²) = 120
Entered annual useful heat demand (kWh/m²/year) = 100
Entered efficiency factor in the chosen heat basis (%) = 95
Entered gas energy per m³ (kWh/m³) = 10.5
Entered gas price per m³ = 3
Fixed charge for the entire year = 0
|
Annual useful heat (kWh): 12000
Annual gas energy input (kWh): 12631.57895
Estimated annual gas volume (m³): 1203.007519
Rounded variable annual charge: 3609.02
|
| 2 |
Heated floor area (m²) = 150
Entered annual useful heat demand (kWh/m²/year) = 60
Entered efficiency factor in the chosen heat basis (%) = 105
Entered gas energy per m³ (kWh/m³) = 10.5
Entered gas price per m³ = 3.2
Fixed charge for the entire year = 480
|
Annual useful heat (kWh): 9000
Annual gas energy input (kWh): 8571.428571
Estimated annual gas volume (m³): 816.3265306
Rounded variable annual charge: 2612.24
|