Dew Point Calculator

Calculate dew point in °C or °F, absolute humidity and a surface condensation comparison.

Dew point
—
Absolute humidity (g/m³)
—
Surface at or below dew point
—
Air temperature minus dew point
—
Surface temperature minus dew point
—
Surface comparison
—
Source humidity comfort category
—
Air-to-dew-point gap
—

Liquid-water Magnus approximation: air temperature and dew point must both be −45…60°C. Relative humidity must be above 0% and at most 100%; 0% has no finite dew point. Surface temperature uses the selected unit. A surface at or below dew point may condense moisture. This is not a frost-point calculation.

Temperature results and differences use the selected °C or °F. The archived coefficient option reproduces both sources; absolute humidity always uses 17.62/243.12. Surface margins are classified at 0°C and 2°C; the air gap at 3°C. Comfort categories reproduce subjective source thresholds at dew points 50/60/65/70/75°F and are not health or building-safety assessments. Comparisons use unrounded model results. Switching units converts entered temperatures with display rounding.

How dew point is calculated

Calculate dew point in °C or °F, absolute humidity and a surface condensation comparison.

Liquid-water Magnus approximation: air temperature and dew point must both be −45…60°C. Relative humidity must be above 0% and at most 100%; 0% has no finite dew point. Surface temperature uses the selected unit. A surface at or below dew point may condense moisture. This is not a frost-point calculation.

γ = ln(RH/100) + 17.62T/(243.12+T); Td = 243.12γ/(17.62−γ); AH = 216.7 × 6.112 × (RH/100) × exp(17.62T/(243.12+T)) / (273.15+T).

Temperature results and differences use the selected °C or °F. The archived coefficient option reproduces both sources; absolute humidity always uses 17.62/243.12. Surface margins are classified at 0°C and 2°C; the air gap at 3°C. Comfort categories reproduce subjective source thresholds at dew points 50/60/65/70/75°F and are not health or building-safety assessments. Comparisons use unrounded model results. Switching units converts entered temperatures with display rounding.

Frequently asked questions

What does a high dew point mean?

A higher dew point means more moisture is actually present in the air, which generally feels more humid and uncomfortable. A dew point above about 65°F (18°C) is commonly considered to feel muggy, and above 75°F (24°C) is considered oppressive.

Why is dew point a better humidity indicator than relative humidity?

Relative humidity is a percentage relative to the air's maximum moisture capacity at the current temperature, so it changes throughout the day even if the actual moisture in the air stays constant. Dew point reflects the absolute moisture content directly, making it more consistent.

Can the dew point be higher than the air temperature?

No — the dew point can never exceed the current air temperature. When the air temperature equals the dew point, the relative humidity is 100% and condensation (like dew, fog, or clouds) begins to form.

How we verified this calculator

The calculator is checked against 6 reference cases computed independently of its code. Last passed: .

# Inputs Expected result
1
Temperature unit = Celsius (°C)
Dew-point coefficients = Existing model: 17.62 / 243.12
Air temperature = 25
Relative humidity (%) = 60
Surface temperature (optional) =
Dew point: 16.6931490062
Absolute humidity (g/m³): 13.7806674587
Air temperature minus dew point: 8.3068509938
2
Temperature unit = Celsius (°C)
Dew-point coefficients = Existing model: 17.62 / 243.12
Air temperature = 25
Relative humidity (%) = 60
Surface temperature (optional) = -40
Dew point: 16.6931490062
Absolute humidity (g/m³): 13.7806674587
Air temperature minus dew point: 8.3068509938
Surface temperature minus dew point: -56.6931490062
3
Temperature unit = Celsius (°C)
Dew-point coefficients = Existing model: 17.62 / 243.12
Air temperature = 25
Relative humidity (%) = 60
Surface temperature (optional) = 10
Dew point: 16.6931490062
Absolute humidity (g/m³): 13.7806674587
Air temperature minus dew point: 8.3068509938
Surface temperature minus dew point: -6.6931490062
4
Temperature unit = Celsius (°C)
Dew-point coefficients = Existing model: 17.62 / 243.12
Air temperature = 25
Relative humidity (%) = 60
Surface temperature (optional) = 30
Dew point: 16.6931490062
Absolute humidity (g/m³): 13.7806674587
Air temperature minus dew point: 8.3068509938
Surface temperature minus dew point: 13.3068509938
5
Temperature unit = Celsius (°C)
Dew-point coefficients = Existing model: 17.62 / 243.12
Air temperature = 0
Relative humidity (%) = 100
Surface temperature (optional) =
Dew point: 0
Absolute humidity (g/m³): 4.84887570932
Air temperature minus dew point: 0
6
Temperature unit = Celsius (°C)
Dew-point coefficients = Existing model: 17.62 / 243.12
Air temperature = 0
Relative humidity (%) = 100
Surface temperature (optional) = -40
Dew point: 0
Absolute humidity (g/m³): 4.84887570932
Air temperature minus dew point: 0
Surface temperature minus dew point: -40

How we test our calculators →

Also try:

Back to category →